Bussmann FRS-R-100

Bussmann Fusetron™ FRS-R-100 Current Limiting Renewable Time Delay Fuse, 100 A, 600 VAC/300 VDC, 20/200 kA Interrupt, RK5 Class, Cartridge Body

Brand: Bussmann

Item ID: 6049

MPN: FRS-R-100

Login for Price

Features

  • Provides motor overload, ground fault and short circuit protection
  • When used in circuits subject to surge currents such as those caused by motors, transformers and other inductive components, these fuses can be sized close to full-load amps to give maximum over current protection
  • The time delay feature makes it possible to use fuse amperage ratings which are much smaller than those of non-time delay fuses
  • Considerable cost savings occur by permitting the use of smaller size switches, panels and fuses themselves
  • Provides a good deg of short circuit protection (greater current limitation) to help protect downstream components from high fault currents
  • Gives motor running back-up protection to motors without extra cost
  • Helps protect motors against burnout from overloads and single phasing when sized properly
  • Simplifies and improves blackout prevention (selective co-ordination ratios)
  • Dual element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection

Description

Bussmann's UL Class RK5 Fusetron product offering provides energy efficient advanced protection with its dual-element, time-delay construction and is available with optional open fuse indication on select ratings. Available in both 250Vac and 600Vac, 200kA RMS Sym interrupting rating and sizes ranging from 0 to 600 amp. Fusetron's deliver 10 seconds (minimum) of time-delay at 500% of rated current (8 seconds for 1/10-30A sizes).

Bussmann Fusetron™ Time Delay Fuse, Current Limiting Renewable, Series: FRS-R, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 100 A, 600 VAC/300 VDC, 20/200 kA Interrupt, Class: RK5, 10 s at 500% Response, Blade Terminal, Holder Mount, Cartridge Body Type, Dual Element, Fiberglass, 1.11 in Dia x 7.88 in L Body Size

Specifications

Amperage Rating

100 A

Body Size

1.11 in Dia x 7.88 in L

Body Type

Cartridge

Class

RK5

Element

Dual

Indicating/Non-Indicating

Non-Indicating

Interrupt Rating

20/200 kA

Material

Fiberglass

Mounting Type

Holder

Rejection/Non-Rejection

Rejection

Response Time

10 s at 500%

Series

FRS-R

Terminal Type

Blade

Type

Current Limiting Renewable

Voltage Rating

600 VAC/300 VDC

Standard Approval

CE Certified|CSA File No. 53787 C22.2/248.12 1422-02|UL 248-12/File No. E4273|UL Guide JDDZ

Application

Combination Starters, Machinery Disconnects, Motor Control Centers and Power Panelboard Applications, Safety and Security Systems

Documentation

Catalog https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_c85790299cf54e7461bd1f247fc23e8817bf201e0cbc9266bf262bd79c0a3cd8.pdf

Line Drawing https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_1423be417d2df19e2fe6f46a335f01eddc5cbbc202c4f2cbb79de8dce35fa8e7.pdf

Specification Sheet https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_bff0c364c618e6b2b2cb3da4ac4263acf2b3d5ddeab4a0fead7612c33194ef38.pdf

Technical Bulletin https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/Edison_REN_10_Technical_Bulletin.pdf

videoVIDEO LINK https://www.youtube.com/watch?v=YMvqUyoETXk

Bussmann FRS-R-100